Use Case:
We have OIC to ERP Bulk import Integration and once import gets completed, we are calling another sub-integration to get the callback from ERP.
To get callback, we are calling BI publisher report in the subintegration and place the callback file in the SFTP directory.
In production, we are observing 5 mins time limit exceeded error while invoking the client ERP BI service and integration gets failed and we are not receiving the Callback file. As a result, we need to manually generate the callback file from ERP for further processing.
What we do:
- One - Retry the ERP callback call atleast 5 times before it finally gets failed.
- Two - In every retry, we have to check if we receive the callback file in the SFTP server directory. That file also check loops five times.
Integration flow:
Steps in detail:
Step1: Take a assign and create a Variable ControlReportExists
p_controlReportExist : false
p_ExceptionCode: ""
p_ExceptionReason: ""
p_ExceptionDetails: ""
p_callBackCount: 0.0
Step2: Take a while and loop it for five times.
$p_controlReportExist: "false" and $p_callBackCount <=4.0
Step3: Take a scope and call the callback subintegration and assign the customized Exception code, reason and details.
Step4: Take a assign for initiate file check count
p_FileCheckCount =0
Step5: Take a while loop and loop it for 5 times to check the file exist in the SFTP directory.
$p_FileCheckCount <=4.0 and $p_controlReportExist="false"
Step6: Call FTP with list operation and required File pattern and direcrory details.
Step7: Take a switch and
if ItemCount =0,
Assign,
p_controlReportExist= "false"
p_FileCheckCount=$p_FileCheckCount + 1.0
Wait 59 sec
Else,
p_controlReportExist= "true"
Step8: take a assign and increase the callback counter by 1.
p_callbackCount =$p_callbackCount + 1.0
Conclusion:
This retry logic will save manual work and tine and most cases(99%), it will work smoothly and gets the callback file.
No comments: